USING THE HOB - INDUCTION
Heater Errors &
Alarms
Fault Description
Turn the controls to the off postion and turn the power off and back on to
reset the system
F / 5 Communication error
Turn the controls to the off postion and turn the power off and back on to
reset the system
F / 1
Induction heater temperature sensor (NTC)
error
Turn the controls to the off postion and turn the power off and back on to
reset the system
F / 2
Induction heater temperature sensor (NTC)
error
Turn the controls to the o
ff postion and turn the power off and back on to
reset the system
F / 8
Induction heater temperature sensor (NTC)
error
Turn the controls to the off postion and turn the power off and back on to
reset the system
F / 7
Induction heater temperature sensor (NTC)
error
Turn the controls to the off postion and turn the power off and back on to
reset the system
F / 9 Induction generator relay error
Turn the controls to the off postion and turn the power off and back on to
res
et the system
F / 3
Induction generator heatsink temperature
sensor (NTC) error
Turn the controls to the off postion and turn the power off and back on to
reset the system
F / 4
Induction generator heatsink temperature
sensor (NTC) error
Turn the controls to the off postion and turn the power off and back on to
reset the system
F / 6 Mains zero crossing loss
Ask your installer to confirm the correct connection to the power supply,
ensuring the required links are in place.